About 2464 Multi Core Wire
Special Features
- STYLE 2464 : Multi-conductor cable using Extruded Non-integral Jacket.
- RATING : 80 deg C, 300 Vac, Cable flame.
- INSULATED CONDUCTOR : Labeled or complying with manufacturer's AWM Procedure.
- CONDUCTOR : 20 AWG - 2 AWG
- ASSEMBLY : Two or more singles, twisted pairs of groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
- COVERING : Optional
- SHIELD : Optional
- JACKET : Extruded PVC
- COVERING : Optional, braid.
- STANDARD : Appliance Wiring Material UL 758.
- USE : Internal wiring or external interconnection of electronic equipment.
Diameter of cable under jacket |
Minimum average thickness |
Minimum thickness at any point |
0.700 inch or less |
30 mils |
24 mils |
0.701-1.000 inch |
45 mils |
36 mils |
1.001-1.500 inch |
60 mils |
48 mils |
1.501-2.500 inch |
80 mils |
64 mils |
2.501-4.000 inch |
110 mils |
88 mils |
4.001 inch and larger |
140 mils |
112 mils |
-
Fill the details and We’ll get back to you soon